Diagram - Single Environment
RAM (GB)
|
web |
db |
geo |
total |
---|---|---|---|---|
DEV |
3 |
4 |
5 |
12 |
QA |
4 |
8 |
8 |
20 |
PROD |
4 |
8 |
8 |
20 |
TOTAL |
|
|
|
48 |
DISK (GB)
|
web |
db |
geo |
total |
---|---|---|---|---|
DEV |
10 GB |
32GB |
200GB |
242GB |
QA |
10 GB |
32GB |
200GB |
242GB |
PROD |
10 GB |
32GB |
200GB |
242GB |
failover
Application failover must be achieved within 2-4 hours and proceeds several ways depending on the nature of the failure. Here we discuss fail-over only in the context of lost connectivity to the data center with an uncertain time to restore operations at that datacenter. When there is a configuration change, either at the VM level or at the application level, we clone the entire application and store it offsite (at the city?). Should the datacenter fail badly (fire, etc), we provide carinet with the application, and carinet brings up the application at another location.
portibility
We plan to move the application to our data center by midyear 2011. We want to insure that the application is portable. The chips in our data center will be Intel Xeon. We expect to do a VM copy (or similar) and do not need v-motion. Does this all seem right?
vm admin
We're planning to use VMware vSphere Essentials Kits to manage the VMs. This will be a Carinet responsibility to setup the Essential Kits on all VMs, SFGov should be able to connect to the VMs remotely via vSphere Client.
SE Linux
Do not enable SE Linux.
SSH Access
All VMs shall be accessible via ssh.
The city will provide public keys for those that will have linux root access.
linux services
All services shall be disabled unless otherwise requested.
Specifically, the following shall be disabled
- NFS
- FTP
- incoming mail
And the following shall be enabled
- outgoing mail
- SSH
- firewall (see below)
firewall
Allow access only as specified in the deployment diagram.